SKU: 88610022, 624.103.090
Price on request
5 People watching this product now!
Kromschroder BCU460-3/1W3GBS3 88610022 is an automatic gas firing device control, managing, igniting, and monitoring gas burners for both intermittent and continuous operation. With a fully electronic design, it swiftly responds to diverse process requirements, making it suitable for frequent cycling.
Krom schroder BCU460-3/1W3GBS3 88610022 gas burner safety control box accommodates directly ignited industrial burners of any capacity, whether modulating or stage-controlled, and is installed near the burner for monitoring purposes. On industrial furnaces, it reduces the central furnace control workload by handling burner-specific tasks, ensuring safe ignition after restarts.
Service personnel benefit from a user-friendly visualization system for input/output signals and error history. A new power management scheme lowers installation and wiring costs, with power for valves and the ignition transformer supplied via the control box’s power supply, safeguarded by a replaceable fine-wire fuse. This setup contrasts with conventional systems used in industrial furnace and kiln construction, which require extensive signal processing over large distances.
Kromschroder BCU460-3/1W3GBS3 88610022 control unit technical data
- For grounded and ungrounded mains
- Inherent consumption: approx. 9 VA plus inherent consumption of the integrated ignition transformer
- Signal and control line: max. 2.5 mm2
- Cable for burner ground/PE wire: 4 mm2
- Is supplied for two cable glands with one seal insert each for cable diameters between 7 and 12 mm
- Flame control with UV detector or ionization sensor
- Flame signal for ionization control: 1 – 28 μA, UV control: 1 – 35 μA
- For intermittent or continuous operation
- Maximum length of ignition cable with integrated electronic ignition: 5 m
- Maximum length of ionization/UV cable: 50 m
- Ambient temperature: -20 to +60°C, no condensation permitted
- Enclosure: IP 54 pursuant to IEC 529
- Weight: 5.1 kg
- Standard version
- Safety time on start-up tSA: 3 s
- Safety time during operation tSB: 1 s
- Mains voltage: 230 V AC, 50/60 Hz
- Front film in English with additional stickers in D, F, I, NL, E
- 3 start-up attempts
- 04 Switch-off threshold, burner/pilot burner: 1 micro A
- 12 Fault lock-out in the event of burner failure in operation
- 15 Flame simulation check in start-up position/standby
- 20 Minimum burner on time tB: 3 s
- 21 Minimum burner pause time tBP: 0 s
- 23 Burner/pilot burner flame proving period tFS1: 0 s
- 34 Burner on time in Manual mode limited to 5 min
- Pre-wired for double-electrode operation
- Minimum time between two start-ups: 10 s
Kromschroeder BCU460-3/1W3GBS3 88610022 control box wiring
- Suitable for hard wiring only.
- Do not reverse phase and neutral conductor.
- Different phases of a three-phase current system must not be installed at Kromschroeder BCU460-3/1W3GBS3 88610022 gas burner control unit.
- No voltage may be connected to the valve and ignition outputs.
- No gas valve may be connected to the air valve output.