Kromschroder 88610019 BCU460-5/1LW3GB is an automatic gas firing device control for industrial burners. Its electronic design ensures quick response to process demands, suitable for frequent cycling. It handles burners of any capacity, reduces central furnace control workload, and guarantees safe ignition after restarts. The user-friendly visualization system aids maintenance, while a new power management scheme cuts installation costs. Power for valves and the ignition transformer is supplied through the control box’s power supply, protected by a replaceable fine-wire fuse, simplifying signal processing compared to conventional systems.
Kromschroder BCU460-5/1LW3GB 88610019 control unit technical data
- For grounded and ungrounded mains
- Inherent consumption: approx. 9 VA plus inherent consumption of the integrated ignition transformer
- Signal and control line: max. 2.5 mm2
- Cable for burner ground/PE wire: 4 mm2
- Is supplied for two cable glands with one seal insert each for cable diameters between 7 and 12 mm
- Flame control with UV detector or ionization sensor
- Flame signal for ionization control: 1 – 28 μA, UV control: 1 – 35 μA
- For intermittent or continuous operation
- Maximum length of ignition cable with integrated electronic ignition: 5 m
- Maximum length of ionization/UV cable: 50 m
- Ambient temperature: -20 to +60°C, no condensation permitted
- Enclosure: IP 54 pursuant to IEC 529
- Weight: 5.1 kg
- Standard version
- Safety time on start-up tSA: 5 s
- Safety time during operation tSB: 1 s
- Air valve control
- Mains voltage: 230 V AC, 50/60 Hz
- Front film in English with additional stickers in D, F, I, NL, E
- 04 Switch-off threshold, burner/pilot burner: 1 micro A
- 12 Fault lock-out in the event of burner failure in operation
- 15 Flame simulation check in start-up position/standby
- 20 Minimum burner on time tB: 5 s
- 21 Minimum burner pause time tBP: 0 s
- 23 Burner/pilot burner flame proving period tFS1: 0 s
- 30 Air valve can be activated externally
- 31 Air valve cannot be activated externally on start-up
- 32 Air valve can be activated in the event of malfunction
- 34 Burner on time in Manual mode limited to 5 min
- Pre-wired for double-electrode operation
- Minimum time between two start-ups: 15 s
Kromschroeder BCU460-5/1LW3GB 88610019 control box wiring
Krom schroder BCU460-5/1LW3GB 88610019 gas control unit is suitable for hard wiring only. Do not reverse phase and neutral conductor. Different phases of a three-phase current system must not be installed at Kromschroder BCU460-5/1LW3GB 88610019 control unit. No voltage may be connected to the valve and ignition outputs. No gas valve may be connected to the air valve output.