Kromschroeder IFS110IM-5/1/1N (84367170) burner control unit

SKU: 84367170, 624.103.068

Price on request

2 People watching this product now!

Krom schroder IFS110IM-5/1/1N 84367170 gas burner safety control boxes are innovative devices for efficient ignition and control of gas burners in continuous operation.

Kromschroeder 84367170 IFS110IM-5/1/1N gas burner safety control boxes features

  • Flame simulation check before starting and after switching the burner off
  • Suitable for ignition and ionization control with one electrode
  • Modern technique using semi-conductors
  • High cycling frequency
  • Flame control by means of ionization electrode or UV-cell
  • Remote reset
  • External fault indication
  • EC tested and certified design

Kromschroder 84367170 IFS110IM-5/1/1N gas burner control box technical data

  • Operating voltages: 220/240 V, 50/60 Hz
  • State voltage and safety time on order
  • Remote reset: yes
  • Power consumption: 5 VA
  • Contact load: max. 1 A per output
  • Total load: max. 2 A
  • Ionisation electrode: 220 V
  • Ionisation current: > 1 µA
  • Reaction time: < 1s
  • Fault indicator: lamp in the reset button and connection for external fault indicator
  • Ambient temperature: -20 °C to +60 °C
  • Protective grade: IP 40 acc. to DIN 40 050
  • Cable gland: for Pg 9
  • Fitting positon: arbitrary
  • Weight: 750 g

Kromschroeder 84367170 IFS110IM-5/1/1N automatic gas firing device operation

Upon thermostat activation, the control system checks for flame simulation and failsafe within the testing time. If no flame signal is detected, the burner starts with voltage applied to valve 1 and the ignition transformer. If flame simulation is detected, the testing time extends up to 10 seconds before entering lockout. Following burner start, a flame signal must be detected within the safety timeframe, triggering valve V2 opening. If no flame is detected, a fault-lockout occurs. Continuous flame signal monitoring occurs during burner operation, also after shutdown. If the flame persists after shutdown, a fault-lockout is initiated, indicating both internally and externally. The IFS 111 IM model applies voltage to external fault indication only upon thermostat activation. Resetting from fault-lockout is possible via internal or external push-button.

Kromschroder 84367170 IFS110IM-5/1/1N automatic burner control unit construction

The housing is made of impact-resistant plastic. The upper housing features a controller and amplifying stage, along with a reset button (labeled as A) and fault indication at the top. It includes a plug socket with terminals, an earthing strip, and retaining screws. Seven openings for cable glands sized Pg 9 (labeled as B) are available. The device complies with applicable standards, including DIN 4788 and VDE regulations.