SKU:
S4965CM1050B, 534.412.054
Price on request
2
People watching this product now!
Designed to optimize the operation of gas domestic heating systems, the Honeywell S4965CM1050B gas burner control box cooperates with VK41… series gas regulators to create a reliable system. This system is an optimized subsystem of emergency protection, providing programmed safe ignition and flame control of the main burner of the heating system, as well as a subsystem for comfortable regulation of the boiler, controlling the temperature and operation of the pump and 3-way valve.
Most of the standard gas boiler control functions can be performed using a single control unit that easily switches to gas regulation.
The HONEYWELL S4965CM 1050BU control unit is suitable for the DANKO 23 3KE boiler.
The model of the Honeywell S4965CM1050U boiler controller includes:
– Smooth regulation: This version of the gas regulator provides smoother and more precise control of the gas combustion process.
– Conventional combustion in the atmosphere: Guarantees reliable without the need for additional devices.
– With fan: The fan contributes to more efficient gas combustion.
General Specification
• Mains voltage 230V +10 -15%
• Network frequency 50 Hz +/- 2%
• Power consumption 4 VA per hour
• External outputs 230 V, maximum 4 outputs; 230 V 0.8 A each; total 2 A
• Valve output 230 V AC 50 mA; modulating or on/off.
• Ambient temperature -20..60°C
• Humidity not more than 90% at a temperature of 40 °C
• External communication 2400 baud
• Flame detection phase-phase
• Electromagnetic filter included
• Compatible with Y-plan N
• Input current consumption 230 V
• Electromagnetic protection level, (D) Internal, (I) Industrial D
• Blocking in the absence of air detection is enabled, if applicable
• Input current consumption 230 V 1 mA or via communication channel
• Non-volatile blocking
Connection
• Multi-position molex minifit connector for 230
• V molex microfit for low voltage
• High voltage spark and ground 2.8 x 0.5mm faston
• Flame rod 4.8 x 0.8mm faston
Specification of the operating system number
• (D) direct burner / (I) constant control ignition D
• (A) atmospheric (F) auxiliary F
• Pre-preparation/waiting time(s) 0
• Pre-ignition time (s) 0.2
• Safe time (s) 7.2
• Number of ignition attempts 3
• Flame failure response time (s) 1
• Stabilization time (s) 0
• Time(s) after cleaning 10
• Pumping time (s) 180
• Cycle protection time (s) 180
• Reset/Alarm: (I) ntegral / (R)emote R
• Ignition/Flame detection: (C) combined / (S) individual S
• Ignition: in (G)nd / (Cl)osed contour G
• Spark frequency (Hz) 15
• Spark Pulse Energy (uAs) 5
• Minimum open spark voltage (kV) 15
Application
The CVI system can be used in various types of heating devices, including flow-through water heaters, floor boilers, combined boilers, boilers with low emission of nitrogen oxides (Low Nox) and condensing boilers.
EMC Instructions
To ensure long-term and reliable operation, it is recommended to follow the instructions on electromagnetic compatibility (EMC), such as:
– Place the boiler regulator in a place with a low temperature and low radiation level.
– Ensure that the boiler regulator is well shielded to suppress RF interference.
Standards
The Honeywell S4965CM1050 automatic gas firing device complies with European standards such as EN 298 and EN 60730, providing safe and efficient management of gas heating systems.
Brand |
---|