Honeywell S4565TM1005 gas boiler control unit

SKU: S4565TM1005U, 534.412.702

Price on request

1 People watching this product now!

The Honeywell burner control unit of the S4565TM1005U series is designed specifically for gas domestic heating installations. The S4565TM 1005U series control box is used in conjunction with VK4105G gas control (EN2R-9025 product manual) in order to create optimized emergency protection subsystems that ensure safe ignition and flame control of the main burner of the heating system. Ignition regulators S4565 TM 1005U are designed for systems with spark ignition of the burner (DBI systems) having a certain safe ignition time.

The CVI-m system contains a smooth gas regulator with a two-position or NTC regulator and a smooth regulation function or a two-level function, as well as an ignition regulator with a built-in power supply of the actuator for smooth electrical regulation. The Resideo S4565TM1005B series provides excellent performance with high reliability. The S4565TM 1005B series burner control box can be used with DBI systems. The control and regulation unit of the S4565 TM 1005B series is applicable for heating installations with and without a fan, with flame detection devices, soft or hard blocking, additional remote reset and fixed waiting periods. If the flame goes out, the full starting sequence is activated. The characteristics and design of the ignition regulator ensure its easy installation with fixation on VK4105G gas regulators.

The Honeywell burner control unit of the S4565TM1005 model has the following purpose: atmospheric DBI system with fixed or adjustable ignition pressure with variable locking.

General provisions

• All burner control protection functions are combined into one reliable and optimized system.

• Special emphasis in the design was placed on obtaining an optimal system solution in smoothly regulated gas heating installations with a DBI system for ignition of the main burner.

• Convenient installation of the ignition regulator on the gas regulator by simple installation in the connector. This design eliminates electrical installation errors.

General remarks

• Housing: (S) tandard or (F)lame retarding / IPX4 F / –

• Electromagnetic filter Y

• Ambient temperature -15…60 °C

• Humidity 90% R.H. max. (at 40 °C) without condensation

Electrical characteristics

• Supply voltage, power consumption 230 V AC; 50 Hz; no more than 4 VA

• Gas valves designed for VK41..G series

• 230 V AC fan; 50 Hz, no more than 1 A

Electrical connection

• Multi-faceted molex 3003 connector, suitable for molex 3001 connector

• High voltage spark and ground 2.8 x 0.5mm blade terminal

• Flame extinguishing rod 4.8 x 0.8 mm with blade terminal

System operation

The automatic burner controller of the S4565QM 1012 series can create a spark discharge both in a closed circuit and to the ground. If the ionization control unit of the S4565 BM 1080 series with a spark discharge in a closed circuit will be used in installations with a spark discharge to the ground, then it is necessary to ground the upper discharge electrode. The output pressure of the gas valve can be adjusted using an input PWM signal, a two-level relay or an NTC sensor. Before each start of the boiler, the burner controller of the S4565 QM 1012 series checks the internal protective equipment. The time required for such a check is called the TC self-check time.

When heating is required, the time equal to the sum of the self-test (TC) and standby (TW) periods expires before the built-in ignition device and the gas valve are switched on. The spark ignites the gas, and the resulting flame is detected by the flame sensor rod. The ignition device turns off after the preset extended ignition time is over and the flame is established. If the flame does not set within the safe ignition time (TS), the ignition regulator is blocked. If the flame goes out during normal operation, the ignition controller repeats the starting sequence.

Reset the lock

• Hard-locked devices can be reset by pressing the built-in or remote reset button.

• Wait at least 10 seconds before pressing the button.

• Soft-lock devices can be reset by interrupting the mains power twice.

• After blocking, disconnect the mains power for about one second.

• After the mains power is restored, the emergency indicator continues to light.

• Wait 10 seconds and interrupt the power again.

• As soon as the mains power is restored, the emergency indicator will go out and the device will make a new attempt to ignite.

Standards

The Honeywell S4565TM 1005 relay is designed in accordance with European standards:

– EN 298: Automatic control systems for gas burners.

– EN 60730-1: Automatic electrical control devices for household and similar purposes.

With regard to electrical safety, the ignition regulator can be used in installations that meet the electrical safety requirements for household electrical appliances defined by the series of European standards EN 60335.

The Beretta R2933 Honeywell ionization control unit is installed in boilers:

  • kompakt22 CSI,RSI.
  • Mynute 20/20 CSI.