Honeywell S4565P2016U control box

SKU: S4565P2016U, 534.412.157

Price on request

3 People watching this product now!

The combined control and ignition system (CVI) is designed for use in gas boilers, heaters and water heaters equipped with an automatic ignition system. It is based on Honeywell S4565P2016U burner control units and cooperates with VK41 series gas regulators… to provide reliable emergency protection.

Important characteristics of the S456 5P 2016U ignition regulators include:

1. Safe Ignition: CVI guarantees safe ignition and effective flame control on the main burner of the heating system. This minimizes the risk of fire and emergency situations.

2. Flexibility of Settings: The system allows you to program ignition, monitor the flame and adjust the gas flow to both the main and pilot burner. This makes it possible to customize the ignition process for optimal efficiency and stability of the equipment.

The boiler controller S4565P2016B includes various modifications for different types of ignition systems:

– Spark Ignition Of The Burner (DBI): These variants of regulators are designed for systems with spark ignition of the burner and provide a safe ignition time.

– Pilot Burner Ignition (IP): For systems with pilot burner ignition, regulators with the suffix “P” indicate an atmospheric system with spark ignition of the burner, except for soft ignition blocking.

The S4565P 2016B burner control box with a voltage of 220/240 V~ can be directly connected to the electrical circuit of the VK41 series gas regulator. It is important to note that they are not intended to directly affect the flame. They have outstanding characteristics and high reliability, and various modifications are available corresponding to different ignition systems.

In addition, the relay S4565 P 2016B are capable of providing potash ignition. The ignition device (HIS) is connected to the transformer winding and has a floating potential. This adds a level of flexibility and security to the ignition system.

General provisions

• All burner control protection functions are integrated into a reliable system.

• Special attention is paid to optimal solutions for systems with spark ignition of the burner (DBI) and systems with pilot burner (IP) for ignition of the main burner.

• The gas regulator and ignition regulator are designed using time-tested principles.

• The installation of the ignition regulator on the gas regulator is simplified thanks to the connector provided on the top of the regulator.

• The controller can be installed within a 90° angle in any direction from the vertical position of the two-position electric actuator.

Reset the lock

The Honeywell S4565P2016 control and regulation unit can be reset by interrupting the constant power supply.

When heating is requested, the HIS device begins to glow during the incandescent time (Tg). After the glow time (Tg) has elapsed, the gas valve is switched on. The ignition device ignites the gas, and the resulting flame is detected by the flame sensor rod. After the flame is established, a preset extended ignition time can be added. If the flame does not set within the safe ignition time (TS), the ignition regulator is blocked. If the flame goes out during normal operation, the ignition controller repeats the starting sequence.

Standards

The ignition regulator is designed in accordance with European standards:

– EN 298: Automatic control systems for gas burners.

– EN 60730-1: Automatic electrical control devices for household and similar purposes.

With regard to electrical safety, the ignition regulator can be used in installations that meet the electrical safety requirements for household electrical appliances defined by the series of European standards EN 60335.