Honeywell S4565CD2029 gas boiler control unit

SKU: S4565CD2029U, 534.412.705, 39808380, 36507180, 36506840, 39810870

Price on request

2 People watching this product now!

The Joint control and ignition system (CVI) is designed for use in gas boilers, heaters and water heaters equipped with an automatic ignition system. This system uses Honeywell S4565CD2029U firebox machines, which cooperate with gas regulators from the VK41… series, providing reliable protection in case of emergencies. CVI guarantees safe ignition and flame control on the main burner of the heating equipment, and also allows you to configure the ignition process, control the flame and regulate the gas flow for both the main and pilot burners.

The boiler controller S4565CD 2029U includes a variety of variations designed for systems with spark ignition of the burner (DBI) and systems with ignition of the pilot burner (IP), ensuring a safe ignition time. The suffix BF indicates that this is an atmospheric system with spark ignition of the burner.

The Honeywell S4565 CD 2029U burner control unit with a voltage of 220/240 V~ can be directly connected to the electric circuit of the gas regulator from the VK41 series …, however, they themselves do not directly affect the flame. These ignition regulators have outstanding performance and high reliability, and are available in various modifications corresponding to different ignition systems.

General provisions

• All burner control protection functions are integrated into a reliable system.

• Special attention is paid to optimal solutions for systems with spark ignition of the burner (DBI) and systems with pilot burner (IP) for ignition of the main burner.

• The gas regulator and ignition regulator are designed using time-tested principles.

• The installation of the ignition regulator on the gas regulator is simplified thanks to the connector provided on the top of the regulator.

• The controller can be installed within a 90° angle in any direction from the vertical position of the two-position electric actuator.

Reset the lock

The Honeywell S4565CD2029B control box can be reset by pressing its own or external reset button. If the first attempt fails, you should wait at least 15 seconds before trying again.

Standards

The ignition regulator is designed in accordance with European standards:

– EN 298: Automatic control systems for gas burners.

– EN 60730-1: Automatic electrical control devices for household and similar purposes.

With regard to electrical safety, the ignition regulator can be used in installations that meet the electrical safety requirements for household electrical appliances defined by the series of European standards EN 60335.

Relay Ferroli, 39808380, 36507180, 36506840, 39810870 Honeywell works on boilers:

  • PEGASUS 45-56, 23-32 (old), RENDIMAX N EL.
Brand