Honeywell S4564C1000 gas boiler control unit

SKU: S4564C1000U, 534.412.150

Price on request

4 People watching this product now!

The S4564C1000U burner control units can be directly electrically connected to the VR4605.. gas regulator series. Gas regulator of the VR4601 series .. for IP ignition.

General characteristics

• All burner control functions are concentrated in one reliable and

optimized system.

• Specially designed to provide an optimal system solution in gas appliances with a DBI or IP system for igniting the main burner.

• Both gas control and ignition control are based on time-tested design solutions that guarantee reliability.

·• It is easy to install the ignition regulator on the gas regulator by connecting it from above.

·• The orientation of the installation can be within + or – 90° from the vertical position of the operator of the electric on/off valve.

Model

Suffix C: using a fan, direct ignition of the burner.

General remarks

• Application: (D) BI or (I) P D

• Electromagnetic filter Y

• Indicators: (H)D, (A)larm, (F)lame HF

• Humidity 90% R.H. (at 40 °C) without condensation

Electrical characteristics

• Supply voltage, power consumption 230-240 V AC; 50/60 Hz; no more than 5 VA

• Gas valves designed for the VR4600 series

• Fan 220/230 … 240 V AC; 50 Hz, no more than 1 A

Electrical connection

• Molex 3003 multi-position connector, suitable for 3001 connectors (or RAST5, see notes)

• High voltage spark and ground 2.8 x 0.5mm blade terminal

• Flame extinguishing rod 4.8 x 0.8 mm with blade terminal

System operation

When heating is required, the fan power is turned on if the access bud is in the normally closed position. As soon as the access point appears

switches, the pre-purge time (Tp) begins. After Tp, the built-in igniter and gas valve are switched on.

The ignition spark ignites the gas, and the resulting flame is detected by a flame extinguisher.

If the flame is set, the ignition is switched off after a long ignition time (text).

If the flame does not ignite within a safe time (Ts), the ignition control system is blocked and the fan is de-energized. When the access point returns to its original position, the alarm indicator lights up.

If the flame disappears during normal operation, the gas valve closes after the flame failure response Time (TFR) has elapsed, and the ignition control system repeats the start sequence. If the flame disappears within a period less than TFR, no reaction will follow.

If the resistance value of the NTC sensor falls below the threshold value, the gas valve is switched off. After the specified response time (TTBB), the system

the ignition control is restarted if the sensor resistance exceeds the threshold value.

The fan turns on, the APS turns on, and after the pre-purge time (Tp), the built-in igniter and gas valve turn on.

Low voltage operation

The relay S4564C1000U is intrinsically safe at any mains voltage from zero to the maximum set.

The ignition control system operates in accordance with the specification within a specified range of mains voltage and tolerances in this range.

Cut-off limit at low voltage: 173 VAC ± 10 VAC.

When the voltage is below the cut-off limit, when the voltage is lowered, the ignition control is turned off and does not start the program execution sequence.

At voltages between the cut-off limit at low voltage and the lowest value of the mains supply voltage range, the ignition control system operates functionally correctly, with the exception of the ignition frequency for O.S. numbers with high spark energy (15 µA). The parameters are not guaranteed in the specification, but the safety time is not increased, the standby time is not reduced, and the blocking function is guaranteed at mains voltage up to 162 V AC.

At the mains voltage level at which the undervoltage disconnection no longer works, the voltage level is too low to open the gas valve (rated voltage about 150 V AC).

Reliability and service life of the product

The S4564 ignition control system will withstand:

• 500,000 cycles for the operator of the gas safety valve and the main valve.

• 250,000 cycles at maximum loads.

• 6000 blocking operations at maximum loads.

• 1000 hours of sparking (type tested during the continuous sparking durability test).