Honeywell S4561D1001 gas boiler control unit

SKU: S4561D1001U, 534.412.026

Price on request

3 People watching this product now!

The Honeywell S4561D1001U ignition regulator provides automatic ignition and control of atmospheric burners in accordance with EN 298.

Electrical characteristics

• Supply voltage, power consumption 220 V … 240 V AC; 50 Hz; no more than 10 VA

• Gas valves 220 … 240 V; no more than 1 A

ELECTRICAL CONNECTION

• Multi-faceted molex 3003 connector, suitable for molex 3001 connector

• 2.8 x 0.5 mm high voltage spark with blade terminal

• Flame extinguisher and grounding tip of the shovel measuring 6.3 x 0.8 mm

Features

• Flame control

• Built-in spark ignition with a frequency of 5… 50 Hz

• External reset, alarm and high limit connection

• Factory safety timer 0 … 50 s

• Supply voltage 220…240 V

• Complete sequence of operations after flame loss

•Volatile or non-volatile blocking according to EN

• Alarm without heat supply

• Protective impedance on the flame extinguisher

• Extended spark ignition or quick start capability

• Potential-free contact SPST flame indication relay for use in SELV circuits or potential-free SPDT flame indication relay contact for use in line voltage circuits.

Ignition

• Ignition: up to (G) round, (Cl) closed loop or (N) single Cl

• Mode depending on the phase neutrality of the flame sensor

• Flame power DT L

• Spark frequency 12 Hz

• Minimum open spark voltage of 15 kV

General considerations

The Resideo S4561D1001B automatic ignition controller must be blocked from the outside. If the internal fuse is blown due to a short circuit, the automatic ignition controller must be repaired by Honeywell.

To ensure reliable long-term operation, install an automatic ignition regulator in the device together with a low ambient temperature and a low level of thermal radiation.

High temperatures will negatively affect the service life of the product.

For safety reasons, the upper limit thermostat must be connected in series

with comfort regulators to turn off the automatic ignition regulator in case of overheating.

To suppress radio frequency interference (RFI), the automatic ignition controller, including spark igniter cables, must be installed in a sufficiently shielded room.

System operation

When the comfort control system requires heating, a self-check time (Tcheck) and a waiting period (Tw) pass before turning on the built-in igniter and gas valve. The ignition spark ignites the gas, and the resulting flame is detected by a flame extinguisher.

The ignition switches off after a certain time (depending on the elapsed safety time) after the flame is set.

If the flame does not ignite within a safe time (Ts), the automatic ignition control is blocked.

If the flame disappears during normal operation, the automatic ignition controller

repeats the start sequence.

General remarks

• Application: (D) BI or (I) P D

• PCB dimensions 105 x 81 mm

• Mounting holes 4 mm

• Electromagnetic filter –

• Ambient temperature range 0…60 °C

• Humidity 90% R.H. (at 40°C) without condensation