Honeywell S4560M1036 gas boiler control unit

SKU: S4560M1036U, 534.412.073

Price on request

4 People watching this product now!

The Resideo S4560M1036U controller ensures the ignition of the burners and their control in accordance with the EN 298 standard.

General remarks

• Direct (main) ignition of the burner yes

• Intermittent control ignition –

• Flame relay output yes

• Fan support yes

• No internal ignition –

• Flame. a circle. for Italy –

• Quick launch option –

• Flame sens. traffic connection –

• Blocking during flame simulation yes

• Blocking in the absence of ether yes

• Gas valve + GPS connection –

• TTB switch connection –

• Reset input protection –

• Operating card

Timings

• Safe time of 3 s

• Self-test time –

• Waiting time –

• Pre-washing time 30 s

• Stabilization time –

Electrical power

• Supply voltage 220/240 V; 50 Hz; 10 VA

Nominal contact

• Fan 220/240 V; 1 A; SYMBOL COS 70f “Symbol” = 0.6

• Gas valves 220/240 V; 1 A; SYMBOL COS 70 f “Symbol” = 0.6

Electrical connection

• Molex 3001 multi-edge connector

• 2.8 x 0.5 mm high voltage spark with blade terminal

• Flame extinguisher and grounding tip of the shovel measuring 6.3 x 0.8 mm

Lock/Reset

• Non-volatile blocking

• Reset remote manual

General considerations

The Hanivel S4560 M 1036U automatic ignition regulator must be equipped with external fuses to ensure safety. This item does not contain any parts that require maintenance. Any attempt to replace its components may negatively affect the safety of the device and, therefore, is strictly prohibited.

High temperatures can shorten the service life of the automatic ignition regulator. Therefore, in order to ensure long-term uninterrupted operation, it is necessary to place it in the place of the heating installation, where the temperature and radiation are minimal.

If the automatic ignition regulator S4560M1036B is integrated into the installation, the overall protection class must be at least IP 40. This guarantees an appropriate degree of protection from external factors.

To ensure safety and reliable operation, in addition, a maximum thermal relay should be installed, which will automatically turn off the automatic ignition regulator in case of overheating.

To reduce radio interference, spark ignition electrode cables should be installed in a well-shielded compartment. This will help prevent possible interference and ensure stable operation of the system.

Reset the lock

The reset of the automatic ignition regulator Honeywell S4560 B 1006B is performed by an external or internal reset button. If the first reset failed, then wait at least 15 seconds before the second attempt.