Honeywell S4565BF1112 gas boiler control unit

SKU: S4565BF1112B, 534.412.046, 83885617

Price on request

5 People watching this product now!

The combined control and ignition system (CVI) is designed for use in gas boilers, as well as in heaters and water heaters with an automatic ignition system. This system uses Honeywell S4565BF1112 ignition regulators, which work together with gas regulators from the VK41 series.. to provide reliable emergency protection. It guarantees safe ignition and flame control on the main burner of the heating system, and also allows you to program ignition, monitor the flame and regulate the gas flow to both the main and pilot burner.

The S4565BF1112 series includes modifications for systems with spark ignition of the burner (DBI) and systems with ignition of the pilot burner (IP), providing a safe ignition time.

The suffix BF indicates that this is an atmospheric system with ignition by a pilot burner and a built-in timer for safe ignition.

Honeywell S4565BF1112 ignition regulators with a voltage of 220/240 V~ can be directly connected to the electrical circuit of the VK41 series gas regulator. It is important to note that they are not intended to directly affect the flame. Ignition regulators of this series have excellent performance and high reliability, and various modifications are available for different ignition systems.

The De Dietrich 85565610 control unit is designed for installation in De Dietrich gas boilers of the DTG X..N series.

Important Features

– Application: DBI or IP

– Enclosure Type: New or Old N

– Housing: Standard or Flame Retarding / IPX4 S / –

– Ambient temperature range: -15…60 °C

– Humidity: 90% R.H. (at 40°C) without condensation

Electrical characteristics

– Supply voltage: 220/230 V…240 V AC; 50 Hz; no more than 4 VA

– Gas valves for VK4100 series

– Fan: 220/230…240 V AC; 50 Hz, no more than 1 A

Ignition

– Ignition: circular (G), closed loop (Cl), alternating current (G) or direct current (G)

– Ignition and flame extinguishing: separate (S) or combined (C)

– Flame sensor: Phase (P) or phase-vertical (N)

– Flame power: PDT(S), PDT(D) or for Op

– Spark frequency: 6 Hz

– Minimum open spark voltage: 15 kV

General provisions

– All burner control protection functions are integrated into a reliable system.

– Special attention is paid to optimal solutions for systems with spark ignition of the burner (DBI) and systems with pilot burner (IP) for ignition of the main burner.

– The gas regulator and ignition regulator are designed using time-tested principles.

– The installation of the ignition regulator on the gas regulator is simplified thanks to the connector provided on the top of the regulator.

– It is possible to install the regulator within an angle of 90° in any direction from the vertical position of the two-position electric actuator.

Reset the lock

The Honeywell S4565BF1112 ignition regulators can be reset by pressing their own or external reset button. If the first attempt fails, you should wait at least 15 seconds before trying again.

Standards

The ignition regulator is designed in accordance with European standards:

– EN 298: Automatic control systems for gas burners.

– EN 60730-1: Automatic electrical control devices for household and similar purposes.

With regard to electrical safety, the ignition regulator can be used in installations that meet the electrical safety requirements for household electrical appliances defined by the series of European standards EN 60335.

Brand