SKU: 070-3470, 327.520.101
Price on request
5 People watching this product now!
Danfoss 070-3470 RSA95R oil burner pumps used for pumping light fuels and kerosene. It is possible to use 1 and 2 pipe operation modes. It can be used as a transport or feed pump.
Danfoss RSA95R 070-3470 gear pump technical data:
- Viscosity range (in the suction line): 1.3-75cSt(mm2/s)
- Filter area / section: 75/150 cm2/microns
- Pressure range: 5.5-21 bar
- Factory settings: 7+-1 bar
- Max. pressure in the suction/return line: 4 bar
- Shaft rotation speed: 1400-3450 min
- Max. starting torque: 0.30 Nm
- Ambient temperature: -20 to +70 °C
- Storage temperature: -25 to +70 °C
- Fuel temperature: -10 to +70 °C
- Shaft: EN225
Brand |
---|