Brahma 40000002 ECM113 control box

SKU: 40000002, 246.124.131

Price on request

2 People watching this product now!

The Brahma ECM113 40000002 gas control was designed specifically for intermittent atmospheric burners (intermittent systems) used in cooktops, gas stoves and multi-burner grills.

Main characteristics

– EC type certification (CE PIN 0051BT3727) in accordance with the Gas Appliances Regulation (EU) 2016/426;

– Compliant with EU Directives, Electromagnetic Compatibility* EMC (Immunity) 2014/30/EU and Low Voltage Directive 2014/35/EU

– In accordance with EN298:2012 (European standard for automatic control systems for gas and oil burners and flame detection) and EN60730-2-5 (European standard for automatic control using class C software);

– According to EN 30-1-4 (European standard for household kitchen appliances)

– Accurate and repeatable timings;

– Flame control by flame rectification property (ionization);

– Control of one to three independent flame signals is selected using three selectors;

– Remote reset input;

– Output signal of operation and error by LED

– External blocking or residual heat output signal;

– Output of a single automatic shut-off solenoid valve;

– Multiple attempts to re-ignite;

– Possibility of connecting to a symmetrical power supply network.

Technical data

Supply voltage: 100/240 V – 50/60 Hz

Operating temperature range: -20 °C – +85 °C.

Ambient humidity: max. 95% at 40 °C.

Degree of protection: IP 00.

Reaction time in case of flame failure: < 1 s.

Pre-ventilation time (tv/tp): 1.5 sec

Safety time (ts): 3 sec

Waiting time (tw): 1.5 sec

Dimensions: 10.7×8.5×3.6 cm

Brand