Brahma SM592.2 36283341 controllers are a reliable solution for working with atmospheric gas burners and burners with a fan, providing an efficient and independent mode of operation. Equipped with automatic manual reset, these controllers provide easy operation and safe restart of the installation if necessary.
Purpose
of controllers – Brahma SM592.2 36283341 controllers are designed to work with atmospheric gas burners.
– Also designed for burners with a fan, providing an independent (intermittent) mode of operation.
Manual ignition reset
– All automatic ignition of Brahma SM592.2 36283341 controllers are equipped with a manual reset function.
– To restart the installation, you need to use the RESET button, providing ease of management and maintenance.
Technical information
Power Supply: 110 V -120 V – 50/60Hz
Operating temperature: -20 degrees to +60 degrees
Humidity: max. 95% at 40 degrees
Protection: IP 40
Time:
– Pre-ventilation time (tv/tp): 1.5 sec
– Safety time (ts): 10 sec
– Standby time (tw): 1.5 sec
– Flame loss response: < 1 sec
Power consumption, at startup: 20 VA
Energy consumption during operation: 14 VA
Flame control:
– Minimum ionization current:1.2 mA
– Recommended ionization current: 3-5 times more min. ionization current
– Max. cable length: 1 m.
Weight with the pad: 275g.
Dimensions: 8.5×6.8×6.5 cm
Installation and electrical connection recommendations
It is recommended to restart the system daily, taking into account the technical and safety requirements for systems without prolonged combustion. gorenje. Turn on and off the controller only when the power supply is off. The modulator can be installed in any position. Avoid getting water droplets on the controller. Ensure proper ventilation and maintain an optimal temperature to extend the life of the controller. Before installing or replacing the controller, make sure that its type and time characteristics are correct.
Basic provisions on electrical connection
Make sure that the installation complies with national requirements and European standards for electrical safety, such as EN 60335/1prEN 50165. The correct connection of the phase and neutral is necessary to prevent dangerous situations. In case of an error, the controller will switch to manual reset mode after the set start-up safety time is completed. Before starting the system, carefully check the cable connections to avoid damage to the controller and ensure safety. Check that the controller, the metal body of the burner and the main power supply are grounded. Ensure the necessary distance between the ionization cable and the power/ignition cables. Use a well-insulated ionization electrode, protected from moisture and humidity.
Certificates and standards
• Certificate (CE Reg. N° 51BT3691) in accordance with Directives 90/396 and 93/68;
• Compliance with EN 298:2003 (European Standard for gas burner control systems.