SKU:
15910686, 246.820.062
Price on request
4
People watching this product now!
BRAHMA TD1STCSF 15910686 ignition transformers are characterized by ultra-compact overall dimensions and are widely used in gas burners, as well as burners for light and heavy liquid fuels used in both domestic and commercial and industrial installations. They operate on the basis of a high-frequency electronic generator, where the voltage is increased by using a BRAHMA TD1STCSF 15910686 high-voltage transformer with a ferritic core, reaching output values up to 15 kV.
All variants of BRAHMA TD1STCSF 15910686 transformers with ignition cable can be supplied with a filter to reduce electromagnetic interference. In the presence of such a filter, the electronic transformers comply with the requirements of Directive 2004/108/EC, and the use of additional external filters is not required. The BRAHMA TD1STCSF 15910686 transformers also offer versions for continuous operation with a 50% duty cycle for 2 minutes.
Specifications
- The possibility of delivery with an integrated EMC filter;
- 100% duty cycle;
- Light weight and compact size;
- High efficiency and ignition power;
- Low power consumption;
- Single or double-pin high voltage output;
- Various mounting and connecting systems;
- Built-in short circuit protection;
- In gas and liquid fuel burners, the safety of ignition transformers depends on the controller.
Technical information
Number of contacts: 1
Peak output voltage kV: 15
Peak current mA: 45
Frequency of output voltage kHz (1): 6
Frequency of output voltage kHz (2): 10
VA Energy Consumption: 25
Ignition cable connectors: plug-in Ø4 mm
Supply voltage: 220-240 V 50/60 Hz On request: 110-120 V 50/60 Hz
Duty cycle: 100 %
Operating temperature: -10 … +60 °C
Protection: IP00
Recommended electrode spacing (spark distance): 3-5 mm
Max. length of ignition cable: 1.5 m
Standard power cable length: 560mm
Weight: about 360 g.
Installation
- ATTENTION! HIGH VOLTAGE.
- Connect and disconnect the BRAHMA TD1STCSF 15910686 transformer only after the power is turned off.
- The installation is carried out in accordance with national and European standards (e.g. EN60355-1 / EN50165) for electrical safety.
- The installation must ensure that the valve body is connected to the ground to provide protection against electric shock (EN60335-1).
- The transformer is installed in any position.
- Do not place high-voltage cables next to other cables.
- Ensure the appropriate level of protection for this installation.