Brahma 15910650 TC2LVCSF ignition transformer

SKU: 15910650, 246.820.047

Price on request

2 People watching this product now!

BRAHMA TC2LVCSF 15910650 ignition transformers stand out for their amazing compactness and are used in various types of burners, such as gas burners, as well as burners for light and heavy types of liquid fuels. They are used in both domestic and commercial installations, as well as in industrial sectors. The basis for the operation of these transformers is a high-frequency electronic generator, which increases the voltage to high-voltage values using the ferritic core of the BRAHMA TC2LVCSF 15910650 transformer, reaching 15 kV.

All models of BRAHMA TC2LVCSF 15910650 transformers with ignition cable can be equipped with a filter to reduce electromagnetic interference, which allows them to comply with the standards of Directive 2004/108/EC without the use of additional external filters. In addition, BRAHMA TC2LVCSF 15910650 transformers have versions for continuous operation with a 100% duty cycle or with a 50% duty cycle in 2 minutes.

Main Features

  • The possibility of delivery with an integrated EMC filter;
  • 100% duty cycle;
  • Compact size and low weight;
  • High efficiency and ignition power;
  • Low power consumption;
  • Single or double-pin high voltage output;
  • Various mounting and connecting systems;
  • Built-in short circuit protection.

BRAHMA TC2LVCSF 15910650 ignition units comply with the requirements of the “Low Voltage Directive (LVD) 73/23/EEC” directive, having an IMQ permit in accordance with the standards EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2- 3:2000.

Technical specifications

Number of contacts: 2;

Peak output voltage: 2*12 kV;

Peak current: 55 mA;

Output voltage frequency (1): 8.5 kHz;

Output voltage frequency (2): 12 kHz;

Power Consumption: 30 VA;

Supply voltage: 220-240 V 50/60 Hz (can be on request: 110-120 V 50/60 Hz);

Duty cycle: 100%;

Operating temperature: -10 … +60 °C;

Protection: IP00;

Recommended spark distance: 3-5 mm;

Maximum length of ignition cable: 1.5 m;

Standard power cable length: 560mm;

Weight: about 420 g.

Construction

The principle of operation, based on the use of a high-frequency electronic generator, allows you to create a device of compact size and light weight with high ignition power. The electronic circuit and the transformer with a ferritic core are coated with a special compound with high thermal conductivity and a unique expansion coefficient, which provides protection against temperature fluctuations and overloads caused by prolonged operation. The built-in varistor protects the device from possible power surges in the power supply network. Transformers are available in various versions with different number and position of contacts, types of high voltage connections and power cable, with/without an EMC (electromagnetic) filter.

Connections

BRAHMA TC2LVCSF 15910650 high-voltage transformers can be used with Brahma controllers, which can be installed directly on the transformer using M4x45 screws. All transformers can be supplied with either a built-in power cable or a connector for it. The connection of the high-voltage cable is carried out inside the insulator and is available in two versions: threaded connection or connector connection with a diameter of 4 mm. All connectors, including cable connectors, are available on request.

Installation

  • ATTENTION! HIGH VOLTAGE.
  • Connect and disconnect the BRAHMA TC2LVCSF 15910650 transformer only after the power is turned off.
  • The installation must comply with national and European standards (e.g. EN60355-1 / EN50165) for electrical safety.
  • The transformer can be installed in any position.
  • Do not allow high-voltage cables to be placed next to other cables.
  • Ensure the appropriate level of protection for this installation.
Brand