SKU: 15060001, 246.820.086
Price on request
3 People watching this product now!
Ignition transformers BRAHMA T11/A 15060001 are suitable for liquid or gaseous fuel burners.
Peculiarities
– Various connection and fastening systems;
– High discharge power (they are especially suitable for all those applications where long ignition wires are required);
– High efficiency and ignition power.
Technical data
– Supply voltage: 220 V – 50 Hz
– Operating temperature range: -10°C +35°C
– Insulation: polyester resin
– Recommended distance between electrodes: 3 – 5 mm
– Standard power cable length: 550 mm
– Number of poles: 1
– Output peak voltage (KV): 1 x 15
– Output effective voltage (KV): 1 x 9
– Output effective current (mA): 20
– Input effective current (A): 1.1
– Duty cycle: 33% in 3 minutes
– Power consumption (VA): 240
– Weight (kg): 2
– Dust and moisture protection class: IP 00
– Ignition cable connectors: plug Ø6.3 mm
– Dimensions:15×10.1×10 cm
Design
The magnetic core on the spark transformer BRAHMA T11/A 15060001 has the shape of a shell. The secondary windings are centrally grounded. The BRAHMA T11/A 15060001 transformer with ignition cable is equipped with a radio interference suppression shield, which must be connected to a reliable ground to be effective. Two caps, painted with fire-retardant paint, cover the coils and form a single unit with the magnetic circuit.
Each transformer is identified by a fixed letter T (transformer), a series of numbers designating the model, and possibly a letter of the alphabet that identifies the specific mounting system. If the fastening system used is a standard fastening system, the corresponding advisory letter is not inserted into the part reference. For example, part designation T11 refers to a transformer with a standard mounting system, while part designation T11/N corresponds to a transformer T11 with a different mounting system.
Ignition units BRAHMA T11/A 15060001 may have the same electrical characteristics, but different mounting systems, or vice versa.
Compound
The high voltage insulators used in the BRAHMA T11/A 15060001 transformers are of two different types, depending on how the connection to the high voltage cables is made using a screw, a 4mm diameter cylindrical terminal or a 6.3mm diameter cylindrical terminal. Unless expressly stated, a screw terminal is used as the connection terminal. The insulators are made of 30% PBT glass fiber.
Installation
– Carefully! Dangerous voltage may be present.
– Connect and disconnect the ignition transformer only after disconnecting the power source.
– Comply with applicable national and European standards (eg EN 60335-1 / EN 60335-2-102) regarding electrical safety.
– Make sure that the transformer ground and the electrical system ground are well connected.
– Locate a single grounding center, thereby preventing the formation of ring paths of grounding conductors.
– The device can be installed in any position.
– Reduce the length of the ignition cable to a minimum (this reduces parasitic capacitance and the likelihood that the ignition cable will act as an antenna transmitting interference to nearby cables).
– Route the ignition cables along a separate path close to the ground planes (this reduces the influence of interference on other electrical wires).
– Avoid placing high voltage cables near other cables.
– Make sure that the degree of protection is appropriate for the system.
Brand |
---|