Transformers BRAHMA T8/G 15015011 have identical overall dimensions, but have different electrical characteristics and mounting systems.
These BRAHMA T8/G 15015011 igniters are ideal for use in high output or pressure burners for use with light or heavy oil. They are also effective in applications where frequent restarting is required, such as steam boilers, cook ovens and other similar systems.
Technical data
– Supply voltage: 230 V – 50 Hz
– Operating temperature range: -10 °C +35 °C
– Insulation: polyester resin
– Recommended distance between electrodes: 3-5 mm
– Standard power cable length: 700 mm
– Number of poles: 2
– Output RMS voltage (kV): 2 x 6.5
– Output peak voltage (kV): 2 x 11
– Output effective current (mA): 33
– Input effective current (A): 2.1
– Duty cycle: 33% in 3 minutes
– Power consumption (VA): 460
– Weight (kg): 3.5
– Ignition current: 35 mA
– Dust and moisture protection class: IP 00
– Ignition cable connectors: screw Ø2.5 mm
– Dimensions: 15x10x10 cm
Peculiarities
Ignition transformers BRAHMA T8/G 15015011 differ not only in size, but also in the variety of connection and mounting systems, giving users flexibility in choosing the optimal integration option.
With outstanding discharge power, these transformers are designed to operate under high thermal load conditions, providing efficient and stable ignition in high thermal output burners.
The high efficiency and ignition power make the BRAHMA T8/G 15015011 spark transformers the ideal choice for applications that require efficient energy use and reliable ignition.
Design
The ignition units BRAHMA T8/G 15015011 is a structure of column-type transformers equipped with two primary windings and two secondary windings. All windings are insulated with a special high-insulation separator, ensuring reliable insulation between them. To achieve high voltage insulation, a special type of vacuum cast polyester resin is used. The transformer housing is made of pressed metal and covered with enamel.
Each transformer is identified by the letter T (transformer), numbers indicating the model, and, if necessary, additional letters associated with the specific mounting system. When using a standard fastening system, the recommendation letter is not indicated. For example, T8 describes a transformer with a conventional mounting system, while T8/G describes a transformer with a different mounting system.
This approach provides the flexibility to choose between different mounting systems depending on the specific requirements and conditions of use of the ignition transformer.
Compound
The transformers with ignition cable used in the BRAHMA T8/G 15015011 high voltage transformers offer two types of insulators for connecting to high voltage cables:
1. Screw connection insulators:
– In this version, high-voltage cables are connected using special screw connections.
– This type of insulator provides a strong and reliable connection where high voltage cables are secured to the transformer using screws.
2. Rajah type cylindrical terminal insulators (6.3mm diameter):
– In this option, high-voltage cables are connected to the transformer using a cylindrical Rajah type terminal with a diameter of 6.3 mm.
– This type of terminal provides an efficient and safe connection that meets the requirements of the device.
The choice between these two types of isolators gives users the flexibility to install and connect BRAHMA T8/G 15015011 ignition units to suit their specific requirements and preferences.
Brand |
---|