SKU: 15003041, 246.820.011
Price on request
4 People watching this product now!
Transformers BRAHMA T8/A 15003041 have the same dimensions, but differ in electrical characteristics and mounting systems. They are designed for use in high output or high pressure burners operating with light or heavy oil. Suitable for situations with frequent restarts, such as in steam boilers, kitchen ovens and similar systems.
Peculiarities
Ignition transformers BRAHMA T8/A 15003041 not only vary in size, but also provide a variety of connection and mounting systems, which gives users the opportunity to choose the optimal integration option. With outstanding discharge power, they are designed to operate under high heat load conditions, providing efficient and stable ignition in high heat output burners.
Ignition units BRAHMA T8/A 15003041 have high efficiency and ignition power, making them an ideal choice for applications where energy efficiency and reliable ignition are required.
Technical data
– Supply voltage: 230 V – 50 Hz
– Operating temperature range: -10 °C +35 °C
– Insulation: polyester resin
– Recommended distance between electrodes: 3-5 mm
– Standard power cable length: 700 mm
– Number of poles: 2
– Output RMS voltage (kV): 2 x 6.5
– Output peak voltage (kV): 2 x 11
– Output effective current (mA): 33
– Input effective current (A): 2.1
– Duty cycle: 33% in 3 minutes
– Power consumption (VA): 460
– Weight (kg): 3.5
– Ignition current: 35 mA
– Dust and moisture protection class: IP 00
– Ignition cable connectors: plug Ø6.3 mm
– Dimensions: 10.1x8x15 cm
Design
Ignition transformer BRAHMA T8/A 15003041 is a structure made of column-type transformers, with two primary and two secondary windings. All windings are insulated with a special high insulation separator made from a special vacuum cast polyester resin. The body is made of pressed metal coated with enamel.
Each transformer is identified by the letter T (transformer), numbers indicating the model, and sometimes additional letters associated with the specific mounting system. In the case of a standard fastening system, the recommendation letter is not indicated. For example, T8 denotes a transformer with a conventional mounting system, while T8/G denotes a transformer with a different mounting system.
It is important to note that high voltage transformers BRAHMA T8/A 15003041 can have the same electrical characteristics, but different mounting systems, providing flexibility of choice depending on the requirements and conditions of use.
Compound
Transformers with ignition cable BRAHMA T8/A 15003041 in ignition devices can have two types of insulators for connection to high voltage cables: screw connection for strength and reliability, and Rajah cylindrical terminal (6.3 mm) for efficient and safe connection. The choice between them provides flexibility in installation according to the user’s requirements and preferences.
Installation
- Dangerous voltage! Follow safety precautions carefully.
- Connect or disconnect the transformer only when the power source is switched off.
- Comply with national and European safety standards (eg EN 60335-1 / EN 60335-2-102).
- Ensure that the transformer and electrical system are properly grounded.
- Install a single grounding center to avoid ring paths of grounding conductors.
- The device can be installed in any position.
- Shorten the length of the ignition cable to reduce stray capacitance and interference.
- Route ignition cables close to ground to reduce interference with other wires.
- Avoid placing high voltage cables close to other wires.
- Check the security level of the system.
Brand |
---|