Brahma 36223101 SM592.2 control box

SKU: 36223101, 246.124.065

Price on request

1 People watching this product now!

Brahma SM592.2 36223101 controllers are designed to work with atmospheric gas burners and for burners with a fan, with non-constant (intermittent) operation mode.

All automatic ignition Brahma SM592.2 36223101 manual reset: restart the installation by pressing the RESET button.

Certificates and standards

• Certificate (CE Reg. N° 51BT3691) in accordance with Directives 90/396 and 93/68;

• Compliance with EN 298:2003 (European Standard for gas burner control systems.

Technical information

Power Supply: 230V – 50/60Hz

Operating temperature: -20 degrees to +60 degrees

Humidity: max. 95% at 40 degrees

Protection: IP 40

Time:

– Purge (TW) 1.5 sec

– Safety (TS): 5 seconds

– Flame loss response: < 1 sec

Power consumption, at startup: 20 VA

Energy consumption during operation: 14 VA

Flame control:

– Min. Ionization current: 0.5 mA

– Recommended ionization current: 3-5 times more min. ionization current

– Max. cable length: 1 m.

Weight with the pad: 275g.

Dimensions: 8.5×6.8×6.5 cm

Installation Recommendations

–  For technical and safety reasons, the system must be restarted every 24 hours (for systems with non-constant combustion). Gorenje.

–  The controller should be connected and disconnected only when the power supply is turned off.

–  The controller is installed in any position.

–  Avoid getting water droplets on the controller.

–  Proper ventilation and operating temperature ensure a longer service life of the controller.

–  Make sure that the type (code and time characteristics) of the controller are correct before installing or replacing.

Electrical connection

–  The installation must comply with national requirements and European standards (e.g. EN 60335/1prEN 50165) for electrical safety.

–  The phase and neutral must be connected correctly, an error can lead to dangerous situations. In case of non-compliance with the phase-neutral, the controller will operate in manual reset mode at the end of the start-up safety time.

–  before starting the system, carefully check the cable connections. An incorrect connection can damage the controller and compromise security.

–  check the grounding of the controller, the metal housing of the burner and the grounding of the main power supply.

–  Ensure the distance between the ionization cable and the power cables/ignition cables.

–  Use a well-insulated ionization electrode, protected from water and humidity.

Checking at startup

Always check the controller before the first start-up, as well as in case of installation changes or long system downtime.

Reset the lock

When switching to the emergency mode, the reset must be carried out no earlier than 10 seconds later.